Ga naar hoofdinhoud
PUURMODULAIR
  • Construction Timber

    • C24 Structural Timber
    • BSH Glulam Beams
    • Turned Logs
    • Sawn Timber & Decking

    Garden & Landscape

    • Half-Round Logs
    • Garden Palisades
    • Outdoor Decking

    Sauna & Wellness

    • Saunas

    Decorative Elements

    • Decorative Elements
    • Accessories

    Bespoke

    Custom specifications tailored to your project.

    Request Quote
  • Homes
  • Knowledge Base
  • Calculator
  • B2B
Contact
PUURMODULAIR

Premium European timber specification for architects, builders, and dealers.

Products

  • Modular Homes (PM35 / PM70)
  • Structural Timber
  • Glulam Beams
  • Sauna Interiors
  • Decking & Cladding
  • Garden Palisades
  • All Products →

Resources

  • Knowledge Base
  • Species
  • Templates
  • Q&A

Company

  • B2B
  • Contact
  • Privacy Policy
  • Terms & Conditions
  • Cookie Policy

Contact

AllPoint Sp. z o.o.

Aleja "Solidarności" 155/6
00-877 Warszawa
Poland

info@puurmodulair.com

+48 723 550 555

REGON: 221597538

NIP: 5851463808

© 2026 AllPoint Sp. z o.o. All rights reserved.

Designed by Brand House

Wij respecteren uw privacy

Wij gebruiken cookies om uw ervaring te verbeteren. U kunt kiezen welke cookies u accepteert.

  1. Home
  2. Templates
  3. Treated Timber

Sustainability · For Architects

Timber Preservative Treatment Specification (Use Class 1–4)


Timber preservative treatment specification depends entirely on Use Class — getting it wrong leads to either premature rot (under-specified) or unnecessary cost and environmental impact (over-specified). This template covers correct specification per EN 335 and EN 351-1.

Free Download

Download the full Treated Timber specification template

NBS-format clause, common errors checklist, and standards reference. Editable PDF format ready for your tender documents.

We respect your privacy. No marketing email — only project-related technical updates if you opt in later.

Specification Checklist

What to include in your Treated Timber specification

  • Use Class

    UC1 (internal dry) → UC4 (in ground/water contact). Define from EN 335 service environment.

  • Treatment process

    Vacuum-pressure impregnation per EN 351-1 (the only acceptable method for UC3-4).

  • Penetration class

    P1–P9 per EN 351-1. Defines depth of preservative penetration.

  • Retention rate

    kg/m³ active ingredient. Specified per Use Class and species treatability.

  • Active ingredient

    Copper-based (typical), boron, or organic. Specify if specific allergens / restrictions apply.

  • Certification

    WTPC scheme membership or equivalent. Treatment certificate per consignment.

  • Re-treatment of cuts

    On-site cuts must be re-treated with end-grain preservative on UC3-4 applications.

Example Clause (NBS Format)

Pre-written specification clause

TIMBER PRESERVATIVE TREATMENT

Use Class: UC4 (in ground contact / fresh water) per EN 335
Treatment process: Vacuum-pressure impregnation per EN 351-1
Penetration class: P8 minimum
Retention: Per WTPC tables for species and Use Class
Active ingredient: Copper-based water-borne preservative (e.g., Tanalith E or equivalent)

Certification:
- Treatment plant: WTPC (Wood Protection Association) member
- Treatment certificate per consignment, traceable batch number on each piece
- Marking: Treated timber stamp visible on each piece

On-site cuts:
- All cut ends, drilled holes, and re-machined surfaces in UC3 or UC4 service shall be re-treated with end-grain preservative per manufacturer specification
- Provide field application kit with each delivery for site use

Copy and paste this clause into your tender. Adjust dimensions, grades, and project-specific requirements.

Common Errors

Avoid these specification mistakes

Specifying "treated timber" without Use Class

Correction: Always state UC1, UC2, UC3, or UC4 per EN 335. Without it, suppliers default to lowest treatment.

Surface application instead of pressure treatment

Correction: Brush / spray treatment only suitable for UC1. UC3-4 require vacuum-pressure impregnation.

No re-treatment specification for site cuts

Correction: Pressure-treated timber loses protection at every cut. Specify field re-treatment for UC3-4.

Reference Standards

EN 335EN 351-1EN 599-1BS 8417WTPC Scheme

Frequently Asked

Specification questions

What Use Class do I specify for fence posts?

UC4 — fence posts are in ground contact. UC3 (above-ground external) is insufficient and the post will rot at the ground line within 5–10 years.

What Use Class for decking joists?

UC3 if joists are clear of ground (200mm+ clearance) and ventilated. UC4 if joists are within 200mm of ground or in ground contact.

Are treated timbers safe to handle?

Modern copper-based preservatives are safer than older CCA treatments but still require gloves, dust masks during cutting, and avoiding contact with potable water sources. Read the WTPC handling guidance for the specific treatment.

Need a tailored quote?

Source Treated Timber from PuurModulair

Our technical team supplies certified, traceable timber matching this specification. Quote within one business hour.