Garden palisade specification combines durability (UC4 ground contact), aesthetic (turned profile), and structural (lateral wind load) considerations. This template covers turned softwood palisades for residential boundaries up to 1.8m height.
Free Download
NBS-format clause, common errors checklist, and standards reference. Editable PDF format ready for your tender documents.
We respect your privacy. No marketing email — only project-related technical updates if you opt in later.
Specification Checklist
Pine, Spruce, or Larch. Pine standard with treatment, Larch acceptable untreated above ground.
Pointed top (traditional), domed top (modern), or flat top. Pointed sheds water best.
60–100mm typical. Larger diameter = more substantial appearance, longer lifespan.
1.0–1.8m above ground. Specify visible height + 600mm below for foundation.
Use Class 4 pressure treatment essential for ground contact. UC3 for above-ground only.
Concrete-set posts or post-supports. Minimum 600mm depth in stable ground.
Top rail for visual continuity, optional middle rail for strength.
Touching (full privacy), 20mm gap (semi-privacy), wider (decorative only).
Example Clause (NBS Format)
TURNED TIMBER PALISADE FENCE Palisades: - Species: Pine (Pinus sylvestris) - Profile: Turned cylindrical with pointed top (4-pyramid cut) - Diameter: 80mm - Visible height: 1500mm above ground level - Below ground: Additional 600mm set in concrete - Treatment: Use Class 4 vacuum-pressure preservative per EN 351-1 - Spacing: 90mm centre-to-centre (10mm gap between palisades) Foundation: - Concrete: C20 minimum - Depth: 600mm - Diameter: 200mm - Post setting: Plumbed, with water-shedding concrete cap Connections: - Top rail: 50×100mm, screwed to top of palisades - Optional middle rail: 50×75mm at mid-height for spans over 1.5m Fixings: - All fixings stainless steel A2 minimum - Coach screws into rails: 8mm × 80mm Finish: Untreated (allow to weather grey) OR pre-stained with breathable wood preservative Certification: FSC or PEFC chain of custody required
Copy and paste this clause into your tender. Adjust dimensions, grades, and project-specific requirements.
Common Errors
UC3 treatment in ground contact
Correction: Always UC4 for in-ground portion. UC3 fails within 5–10 years at the ground line.
No concrete foundation
Correction: Direct soil setting with no concrete causes lean and fail. Concrete-set is essential for stability.
Galvanised fixings with Larch
Correction: Larch tannins corrode galvanised steel and cause black streaks. Always stainless steel A2 minimum.
No water shedding detail at top
Correction: Flat tops absorb water and rot. Pointed or domed tops shed water effectively.
Reference Standards
Frequently Asked
Properly treated and detailed: 15–25 years. Untreated pine in ground contact: 3–7 years. Larch above ground: 20–30 years untreated.
Concrete-set is most durable (lifespan matches palisade). Steel post-supports allow easier replacement but the metal-timber junction can rot prematurely if not detailed correctly.
For heights above 1.2m, top rail is mandatory for stability. Above 1.5m, add middle rail. Without rails, palisades flex and gap over time.